LRS-200 Series Power Supply

Product Name: LRS-200 Series Power Supply

Facebook youtube  skype

Description:


    Features
    -AC input range selectable by switch
    -Withstand 300VAC surge input for 5 second
    -No load power consumption<0.75W
    -Miniature size and 1U low profile
    -High operating temperature up to 70degree
    -Protections:Short circut / Overload / Over voltage / Over temperature 
    -Cooling by free air convection
    -Operating altitude up tp 5000 meters
    -High efficiency,long life and high reliability
    -3 years warranty

    Introduction

    1.LRS-200 series is a 200W signal-output enclosed type power supply with 30mm of low profile design.
    2.Adopting the input of 115VAC or 230VAC(select by switch), the entire series provides an output voltage line of 5V,12V, 15V, 24V,ETC.
    3.In addition to the high efficiency up to 90%, the design of metallic mesh enhances the heat dissipation of LRS-200 that the whole series operates from -25 degree through 70degree under air convection without a fan.
    4.Delivering an extremely low no load power consumption (less than 0.75W), it allows the end system to easily meet the worldwide energy requirement. LRS-200 has the complete protection functions and 5G anti-vibration capability ; it is complied with the international safety regulations such as UL60950-1 .
    5.LRS-200 series serves as a high price-to-performance power supply solution for various industrial applications.
Specification
MODEL LRS-200-5 LRS-200-12 LRS-200-15 LRS-200-24
OUTPUT DC VOLTAGE 5V 12V 15V 24V
RATED CURRENT 40A 17A 14A 8.8A
CURRENT RANGE 0 ~ 40A 0 ~ 17A 0 ~ 14A 0 ~ 8.8A
RATED POWER 200W 204W 210W 211.2W
RIPPLE & NOISE 
(max.) Note.2
150mVp-p 150mVp-p 150mVp-p 150mVp-p
VOLTAGE ADJ.
 RANGE
4.5 ~ 5.5V 10.2 ~ 13.8V 13.5 ~ 18V 21.6 ~ 28.8V
VOLTAGE TOLERANCE Note.3 ±3.0% ±1.5% ±1.0% ±1.0%
LINE REGULATION   ±0.5% ±0.5% ±0.5% ±0.5%
LOAD REGULATION  ±2.0% ±1.0% ±0.5% ±0.5%
SETUP, RISE TIME 1300ms, 50ms/230VAC     1300ms,50ms/115VAC at full load
HOLD UP TIME (Typ.) 16ms/230VAC   12ms/115VAC at full load
INPUT VOLTAGE RANGE 90 ~ 132VAC / 180 ~ 264VAC by switch
FREQUENCY RANGE 47 ~ 63Hz
EFFICIENCY (Typ.) 87% 87.50% 88% 89.50%
AC CURRENT (Typ.) 4A/115VAC   2.2A/230VAC
INRUSH CURRENT 
(Typ.)
COLD STAR 60A/115VAC                      60A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
110 ~ 140% rated output power
PROTECTION OVER LOAD Protection type : Hiccup mode, recovers automatically after fault condition is 
removed
5.75 ~ 6.75V 13.8 ~ 16.2V 18 ~ 21V 28.8 ~ 33.6V
OVER VOLTAGE Protection type : Hiccup mode, recovers automatically after fault condition is 
removed
OVER 
TEMPERATURE
Hiccup mode, recovers automatically after fault condition is removed
SAFETY WORKING TEMP. -25 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY 20 ~ 90% RH non-condensing
ENVIRONMENT 
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH
TEMP. 
COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY 
STANDARDS
UL60950-1 approved
WITHSTAND 
VOLTAGE
I/P-O/P:3KVAC   I/P-FG:2KVAC   O/P-FG:0.5KVAC
ISOLATION 
RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
OTHERS MTBF 347.5K hrs min.   MIL-HDBK-217F (25℃)  
DIMENSION 215*115*30mm (L*W*H)
PACKING 0.66Kg; 15pcs/10.9Kg/0.78CUFT

Accessories
Download Data
Video

Scroll to top