HLG-150 Series Power Supply

Product Name: HLG-150 Series Power Supply

Facebook youtube  skype

Description:

    Waterproof 150W Single Output Switching Power Supply, the following model widely used with Led Works led lamps;
    HLG-150H-12, HLG-150H-15, HLG-150H-24,etc some other model for special lamps with different input voltage.
     
    Waterproof 150W Single Output with PFC Function

    HLG- 150 series
    Features
     
    1.Universal AC input / Full range
    2.Built-in active PFC function
    3.High efficiency up to 94%
    4.Protections: Short circuit / Over current / Over voltage / Over temperature
    5.Cooling by free air convection
    6.OCP point adjustable through output cable or internal
    7.IP67 / IP65 design for indoor or outdoor installations
    8.Three in one dimming function (1~10Vdc or PWM signal or resistance)
    9.Suitable for LED lighting and street lighting applications
    10.Compliance to worldwide safety regulations for lighting
    11.Suitable for dry / damp / wet locations
    12.5 years warranty 
Specification
HLG-150H-12 Blank : IP67 rated. Cable for I/O connection.
HLG-150H-12A : IP65 rated. Output voltage and constant current level can be adjusted through internal potentiometer.
HLG-150H-12B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or PWM signal or resistance.
HLG-150H-12D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.


Model HLG-150H-12 HLG-150H-15 HLG-150H-24
 
Output DC VOLTAGE 12V 15V 24V
CURRENT ADJ. RANGE Can be adjusted by internal potentiometer A type only
7.5-12.5A 6-10A 3.8-6.3A
RATED POWER 150W 150W 151.2W
VOLTAGE ADJ. RANGE 10.8-13.5V 13.5-17V 22-27V
Input Voltage Range 90-264VAC           127-370V DC
Frequency Range 47-63Hz
POWER FACTOR PF>0.98/115VAC, PF>0.95/230VAC, at full load (Please refer to "Power Factor Characteristic" curve)
Efficiency(Typ.)(230Vac) 92% 92.5% 93.5%
AC CURRENT (Typ.) 1.7A / 115VAC          0.75A / 230VAC
INRUSH CURRENT(Typ.) COLD START 75A/230VAC
LEAKAGE CURRENT <0.75mA / 240VAC
PROTECTION OVER LOAD 95~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 14-17V 18-21V 28-34V
Protection type :Shut down O/P voltage, re-power on to recover
OVER TEMPERATURE 100 ℃ up or less10 ℃ (RTH2)
Protection type : Shut down and latch off o/p voltage, recovers automatically after temperature goes down
Environment WORKING TEMP. -40 ~ +70 ℃(Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 95% RH non-condensing
SAFETY SAFETY STANDARDS UL8750, CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ;
design refer to UL60950-1, TUV EN60950-1
WITHSTAND VOLTAGE I/P-O/P:3.75KVAC   I/P-FG:2KVAC     O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH
EMC EMISSION Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2  Class C ( 50% load) ; EN61000-3-3
EMC IMMUNITY Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV),  criteria A
Others MTBF 192.2K hrs min.      MIL-HDBK-217F (25℃ )
DIMENSION 228*68*38.8mm (L*W*H)
PACKING 1.15Kg; 12pcs/14.8Kg/0.8CUFT
Note 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Type A only.
6. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Refer to warranty statement.

Accessories
Download Data
Video

Scroll to top