Model |
RSP-320-5 |
RSP-320-7.5 |
RSP-320-12 |
RSP-320-15 |
RSP-320-24 |
Output |
DC
VOLTAGE |
5V |
7.5V |
12V |
15V |
24V |
CURRENTRANGE |
0-60A |
0-40A |
0-26.7A |
0 ~ 21.4A |
0 ~ 13.4A |
VOLTAGE ADJ.
RANGE |
4.5-5.5V |
6-9V |
10-13.2V |
13.5 ~ 18V |
20 ~ 26.4V |
Input |
Voltage
Range |
88-264VAC 124-370V DC |
Frequency
Range |
47-63Hz |
POWER
FACTOR |
PF>0.95/230VAC PF>0.98/115VAC at full load |
Efficiency (Typ.) |
83% |
88% |
88% |
89% |
89% |
PROTECTION |
OVER LOAD |
105 ~ 135% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed |
OVER VOLTAGE |
5.75 ~ 6.75V |
9.4 ~ 10.9V |
13.8 ~ 16.2V |
18.8 ~ 21.8V |
27.6 ~ 32.4V |
Protection type :Shut down O/P voltage, re-power on to recover |
Environment |
WORKING TEMP. |
-30 ~ +70 (Refer to "derating curve") |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
SAFETY |
SAFETY
STANDARDS |
UL60950-1, TUV EN60950-1, CCC GB4943 approved |
WITHSTAND
VOLTAGE |
I/P-O/P:3KVAC I/P-FG:2KVAC
O/P-FG:0.5KVAC |
ISOLATION
RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH |
EMI |
Compliance to EN55022 (CISPR22) Class |
EMISSION |
B,EN61000-3-2,-3, GB9254 class B, GB 17625.1 |
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, light industry level, criteria A |
Others |
MTBF |
206.5K hrs min. MIL-HDBK-217F (25℃ ) |
DIMENSION |
215*115*30mm (L*W*H) |
PACKING |
0.9Kg; 15pcs/14.5Kg/0.78CUFT |
Note |
1. All parameters NOT specially mentioned are measured at |
230VAC input, rated load and 25 of ambient temperature. |
2. Ripple & noise are measured at 20MHz of bandwidth by |
using a 12" twisted pair-wire terminated with a 0.1uf & 47uf |
parallel capacitor. |
3. Tolerance : includes set up tolerance, line regulation and |
load regulation. |
4. Derating may be needed under low input voltages. Please |
check the derating curve for more details |
5. The power supply is considered a component which will be |
installed into a final equipment. The final equipment must be |
re-confirmed that it still meets EMC directives. For guidance |
on how to perform these EMC tests, please refer to .EMI |
testing of component power supplies.. |
(as available on http://www.meanwell.com) |
6.For charging related applications, pls result Mean Well for details. |