MODEL |
RSP-500-5 |
RSP-500-12 |
RSP-500-15 |
RSP-500-24 |
OUTPUT |
DC VOLTAGE |
5V |
12V |
15V |
24V |
RATED
CURRENT |
90A |
41.7A |
33.4A |
21A |
CURRENT
RANGE |
0 ~ 90A |
0 ~ 41.7A |
0 ~ 33.4A |
0 ~ 21A |
RATED POWER |
450W |
500.4W |
501W |
504W |
RIPPLE & NOISE (max.) |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
VOLTAGE ADJ.
RANGE |
4.5 ~ 5.5V |
10 ~ 13.2V |
13.5 ~ 18V |
20 ~ 26.4V |
VOLTAGE
TOLERANCE |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
LINE
REGULATION |
±0.5% |
±0.3% |
±0.3% |
±0.2% |
LOAD
REGULATION |
±1.0% |
±0.5% |
±0.5% |
±0.5% |
SETUP,
RISE TIME |
1500ms, 80ms/230VAC 3000ms, 80ms/115VAC at full load |
HOLD UP
TIME (Typ.) |
18ms/230VAC 14ms/115VAC at full load |
INPUT |
VOLTAGE RANGE |
85 ~ 264VAC 120 ~ 370VDC |
FREQUENCY RANGE |
47 ~ 63Hz |
POWER FACTOR (Typ.) |
PF>0.95/230VAC PF>0.98/115VAC at full load |
EFFICIENCY (Typ.) |
84% |
88% |
88% |
89% |
AC CURRENT (Typ.) |
5.3A/115VAC |
2.65 A/230VAC |
|
INRUSH CURRENT (Typ.) |
20A/115VAC |
40A/230VAC |
LEAKAGE CURRENT |
<2mA / 240VAC |
PROTECTION |
OVERLOAD |
105 ~ 130% rated output power |
Protection type : Constant current limiting, recovers automatically after fault condition is removed |
OVER VOLTAGE |
5.75 ~ 6.75V |
13.8 ~ 16.2V |
18.8 ~ 21.8V |
27.6 ~ 32.4V |
Protection type : Shut down o/p voltage, re-power on to recover |
OVER TEMPERATURE |
Shut down o/p voltage, recovers automatically after temperature goes down |
REMOTE CONTROL |
POWER ON:open or 0~0.8VDC between RC+(Pin 4)&RC-(Pin3) on CN100 |
POWER OFF: 4~10VDC between RC+(Pin 4)&RC-(Pin3) on CN100 |
REMOTE SENSE |
Compensate voltage drop on the load wiring up to 0.3V |
FAN CONTROL (Typ.) |
RTH2≧50℃±10℃Fan on ; RTH2≦40℃±10℃ Fan off (Fan always on for 3.3~5V,Fan ON/OFF control for 12~48V) |
ENVIRONMENT |
WORKING TEMP. |
-30 ~ +70℃ (Refer to "Derating Curve") |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
STORAGE TEMP.,
HUMIDITY |
-40 ~ +85℃, 10 ~ 95% RH |
TEMP. COEFFICIENT |
±0.03%/℃ (0 ~ 50℃) |
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY & EMC |
SAFETY STANDARDS |
UL60950-1, TUV EN60950-1 approved |
WITHSTAND VOLTAGE |
I/P-O/P:3KVAC |
I/P-FG:2KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH |
EMC EMISSION |
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 |
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3 heavy industry level, criteria A |
OTHERS |
MTBF |
187.7K hrs min. |
MIL-HDBK-217F (25℃ ) |
DIMENSION |
230*127*40.5mm (L*W*H) |
PACKING |
1.3Kg; 9pcs/12.7Kg/0.7CUFT |